Standard Test Method for Cold Filter Plugging Point of diesel and Heating Fuels

ID metody: 31 • Norma / metoda odniesienia: ​PN-EN 116​:2015

Back to Methods List

Description of the method

Detailed description of the test procedure in the selected language.

Range: + 10 - (-40)

Unit: 0C

Objects: liquid fuels and biofuels, other petroleum products

Summary of Test Method: A specimen of the sample is cooled under specified conditions and, at intervals of 1 0C, is drawn into a pipet under a controlled vacuum trough a standardized wire mesh filter. The procedure is repeated, as the specimen continues to cool, for each 1 0C below the first test temperature. Testing is continued until the amount of wax crystals that have separated out of solution is sufficient to stop or slow down the flow so that the time taken to fill the pipet exceeds 60 s or the fuel fails to return completely to the test jar before the fuel has cooled by a further 1 0C. The indicate temperature at which the last filtration was commenced is recorded as the CFPP.

The CFPP of a fuel is suitable for estimating the lowest temperature at which a fuel will give trouble-free flow in certain fuel systems.

For climate-dependent requirements options are given to allow for seasonal grades to be set nationally. The options are for temperate climates six CFPP grades and for arctic or severe winter climates five different classes.

Parameters and standard

Kluczowe informacje o metodzie badawczej, normie i jednostce pomiaru.
ID_metody: 31 • Typ: 1
Parameter CFPP - ​Temperatura zablokowania zimnego filtra
Unit °C
Standard / method ​PN-EN 116​:2015
Own method Yes
Standard Test Method for Cold Filter Plugging Point of diesel and Heating Fuels